The keypad zone is acknowledged getting a element which has long been on the marketplace on most DSC keypads for several years. Its most standard use is delivering a zone network near to some door, to make certain the fact that doorstep sensor may possibly be attached straight to Z and B near to the keypad, as opposed to operating an even more cable tv to some Z and COM near to the deal with panel. It also permits the installer to expand the method by adding just one hardwired zone, on top of that to people near to the principal board. With two keypads, you can have two even more zones, and so on.
In purchase to take advantage of a keypad zone, the keypad should be assigned to its personal slot (address). at any time you have only just one keypad, then it is presently assigned by default; 5500 keypads are assigned to slot 8, even although all other individuals are assigned to slot 1. This assignment requires place as shortly when you energy up; it is automatic. at any time you have even more than just one keypad in precisely the same exact sort (two or even more 5500′s or two or even more non-5500′s) then you definitely will should manually assign them to numerous slots. To prevent confusion, we will presume that you just are producing utilization of only just one partition in your method (you can’t have zero partitions). To assign a keypad to slot 1, go to THAT keypad and enter:
*8
Installer’s Code
000
0
11
##
Be cautious to key in people digits precisely, or you may possibly wind up using a keypad that appears getting unresponsive (see “Why Is My Keypad Dead??” ). To assign a keypad to slot 2, key in twelve as opposed to 11 (13 for slot 3, 14 for slot 4, etc.). at any time you have even more than just one 5500, just one of them ought getting assigned to slot 8.
Once your keypad is assigned to some slot, you can founded up the keypad zone. In part 020, the very first two digits will be the zone amount for the keypad in slot 1; the following two digits will be the zone on keypad 2, etc. So to assign zone 7 to keypad 1, you would enter:
*8
Installer’s Code
020
07 (zone 7 on keypad 1)
##
To assign zone 7 to keypad 3, you would enter:
*8
Installer’s Code
020
00 (no zone on keypad 1)
00 (no zone on keypad 2)
07 (zone 7 on keypad 3)
##
You will nonetheless should define your keypad zone, just when you would for just about any other zone. You will also should ensure the fact that zone is enabled (assigned to Partition 1) inside the “Partition Assignment” part (202 for zones 1-8, 203 for 9-16, 204 for 17-24, etc.). Depending upon which method you have, zones higher than 6, higher than 8, or higher than 16 may possibly be disabled by default.
One last note: at any time you choose for the keypad zone amid the zones that is produced into your principal board, that zone will not be usable near to the principal board. In other words, at any time you ascertain that you just wish the keypad zone getting zone 1, then you definitely cannot use zone one near to the principal board.
Posted in Uncategorized Tagged: alarm zones, DSC keypad December 25, 2010
Like most current alarm systems, many different DSC panels could possibly be divided into two and even a good offer more separate systems, recognized as “partitions.” Most individual residences by no implies phone for this feature, but there are situations precisely where it is ideal and quite useful. If partitions are used, then a individual could possibly should entry one partition, an extra partition or both/all partitions (“global”). Here’s precisely where the problems occurs: the installer (particularly a earliest time do-it-yourselfer) who is NOT producing utilization of partitions could possibly accidentally assign the keypad as globally (able to entry all partitions). since the keypad can now entry both/all partitions, it will not respond in any way until you inform it which partition to access. So assuming you are not producing utilization of two and even a good offer more partitions, you merely should entry partition one (which is your only partition…. you can’t have zero partitions). PRESS AND preserve THE “1″ essential FOR TWO SECONDS (until it beeps). That’s it…. it’s alive. IT’S ALIVE!!!!! What’s that?? You say it’s even now lifeless like a doornail? odds are that as opposed to getting assigned as global, it absolutely was assigned to some partition, but to some partition other than “1.” No problem; just press and preserve the “#” essential for two seconds (until it beeps), THEN press and preserve “1″ for two seconds. Doctor, we’ve obtained a pulse!!
Now how the keypad is alive, you should permanently correct the problem, so look at on.
To permanently assign the keypad to partition one, do the following:
*8 then Installer’s Code
000 to key in keypad programming
0 to plan partition and slot assignment
1 for partition 1
1 for slot one (or “2″ for just about any next keypad, “3″ for just about any third, etc. or “8″ for an LCD5500, PK5500, or RFK5500 keypad)
## to exit programming
Without the clutter:
*8 Installer’s Code
000
0
1
1
##
Problem fixed. could possibly your keypad reside a extended and healthful life!
Posted in Uncategorized Tagged: control keypad, DSC keypad December 25, 2010
Motion sensors are usually employed to force-shield the inside from the protected place and as this sort of they are usually programmed as both a sort 4 (interior follower) and even a sort 10 (interior with delay).
When the method is armed “away” the motions (type 4) are arranged to trip an alarm the moment in time movement is detected. sort 10 will start the entry delay when tripped providing time to disarm past to alarm.
When the method is armed “stay” the motions (type 4 and 10) are not getting employed and so movement in that place will not be detected.
The alarm method understands for all those people which have left your house or not over the opening of an exterior entry/exit door. for all those people that desire to check the motions as well as you arm “away” the method will instantly change back again to “stay” mode unless you have opened a doorstep like you are leaving or have altered the default setting in *84 (auto stay arm) to “0”. And while in stay mode, the sensors aren’t working.
So to check motions, arm apart then both leave for just about any moment in time or so or in the very minimum available an entry/exit doorstep and near it while standing nevertheless (if your while in the detection area) right up until the method completely arms (beeping stops). Then proceed to stroll throughout the motions detection place right up until alarm goes off.
Wireless Motions:
Wireless motions work essentially a comparable way but possess a specific element that helps make them challenging to check – the battery saver. as quickly since the movement is settled and waiting for motion, it will only trip the moment in time every solitary and every 3-5 mins (check your motion’s instructions) as element from the battery saver design.
Besides truly opening and placing the detector into check mode, you can check them just such as the wired kinds above but should give them that 3-5 mins of wait around time past to wanting to trip them again.
So to check them adhere to the above directions but stay outside or do not proceed for in the very minimum the 3-5 mins so they will reset past for you check them.
Common movement Issues:
Installed upside down: When upside right down the detection zones are pointed toward ceiling and never the floor. It may properly or may properly not detect a human. make particular they are mounted proper part up. occasionally this mounting is employed for spots with dogs, however the detectors are usually mounted merely a tiny lower, say 4-5 ft away the ground.
Installed in the incorrect height: you must adhere to the motions height specifications or even the detection pattern may be severely affected. family pet motions precisely where pets are bundled have exact mounting heights and settings that should be followed.
Installed while in the incorrect place: Motions work finest when mounted in corners as they are almost consistently a 90o broad pattern, this fills the whole space with beams. you need the intruder to stroll throughout the beams and never toward the beams.
Blocked: Motions need a obvious trail toward spots which could be to turn into protected. Shelves, cabinets, plants, etc. can obstruct beams and render the detector blind to people people areas.
Heat or oxygen flow while in the beam areas: Motions are delicate to heat sources, heated curtains (by sunshine or heat vents), drafts, oxygen vents etc. Also any switching or blowing pieces can induce false alarms (balloons, plants, hanging signage, etc.) Do not phase them at fireplaces, furnaces, etc.
The most essential element to finish when mounting a movement detector will be to look at and recognize the directions which could be included. This exercise will response most from the issues you may properly encounter!
Posted in Uncategorized Tagged: alarm sensors, motion detectors December 25, 2010
Just since it requires two to tango, wireless operation needs two items: a r / c transmitter to mail alerts as well as a receiver to collect individuals signals, interpret them, and relay them in the direction of the alarm plan control. Your DSC wireless set up will consist of both a stand-alone receiver or perhaps just one that’s created in to a keypad. In both case, it are steering to be programmed getting a 5132 receiver. That programming is finished in part 804 (your receiver or keypad/receiver will require to possess appear receiving a guide which consists of a Programming Worksheet). almost all the programming will include identifying, or “enrolling” the wireless products to be certain the fact that receiver will recognize them and accept their signals.
Programming part 804 has two-digit subsections, or slots, for every from the devices. Subsections 01 by means of 32 are reserved for zones 1-32, to which wireless sensors could possibly be assigned. Slots 33 by means of 36 are for handheld keypads, and 41 by means of 56 are for vital fobs.
Censors??!! I believed this was a local community forum!!
No, sensors. We’ll start by enrolling them. every sensor consists of a unique electronic Serial amount (ESN), which should be listed using the system. almost just about every ESN consists of letters also to numbers. thinking about that keypads have no letters, the letters should be entered as “HEX” digits. Here’s how it works:
In HEX programming,
1=A
2=B
3=C
4=D
5=E
6=F
“But how,” you ask, “does the plan know it’s an A and never really a 1?” good question! HEX entries possess a * preceding to and after. So “A” is entered as *1*. BC can be *23*.
The ESN 297F35 can be entered 297 *6* 35
The ESN 4B32E7 can be entered 4 *2* 32 *5* 7
The ESN 2C1FD6 can be considered a few of *3* one *64* 6
Remember, the ” * ” tells the plan that you simply are commencing to key in HEX digits and that you simply are finished entering HEX digits.
So now we’re ready to go.
As we mentioned earlier, wireless sensors are enrolled in slots 01 (for zone 1) by means of slot 32 (for zone 32). So to enroll a window transmitter with ESN 2A45B6 as zone 12, you would enter:
*8
Installer’s Code
804 (the part for wireless programming)
12 (the subsection for zone 12)
2 *1* 45 *2* 6 (the ESN)
## (exit programming)
For the zones to work, you need to do a few other things. once the zone amount can be to acquire higher than 8, you need to go into part 203 (for zones 9-16), 204 (for zones 17-24), 205 (for zones 25-32), and so on, and toggle that zone on to be certain that it are steering to be assigned to Partition one (for simplicity, we will presume you are producing utilization of only just one partition). every just one of individuals sections has 8 toggle choices (one for every zone), so in part 203, option one will represent zone 9, option a few of are steering to be zone 10, etc. In part 204, option one are steering to be zone 17, and so on.
The zones should then be defined, just as all zones are, in part 001, 002, etc., depending near to the zone amount as well as your particular system.
Finally, you need to go into part 1XX (where XX are steering to be the zone number) and turn ON option 8 (the wireless attribute). you need to do this for just about every zone which can be to acquire wireless. Be good to finish so subsequent you’ve defined the zones, thinking about that in part 1XX you are altering the default attributes for that definition.
You appears fob-ulous, dahling!!
Key fobs (DSC calls them “wireless keys”) are enrolled in slots 41 by means of 56. in circumstance you have two fobs, you may possibly as well place them in slots 41 and 42. You would do that like this:
*8
Installer’s Code
804 (the part for wireless programming)
41 (the slot for the very first keyfob)
XXXXXX (the electronic Serial amount of fob #1)
42 (the slot for the 2nd keyfob)
XXXXXX (the electronic Serial amount of fob #2)
## (Exit programming)
One extra product for the vital fobs: look at the guide that arrived using the fobs; if they appear with default values for the 4 purpose keys, great! If not, you need to plan them in part 804, subsection 59. The fobs will not hold out unless the purpose keys are defined, both by default or by you. The features are outlined using the manual. So as quickly when you key in part 804, subsection 59, the very first two digits will appear to be the definition for purpose vital #1, the up coming two digits will define vital #2, etc. key in all eight digits with out interruption, just when you have finished in entering zone definitions.
Posted in Uncategorized Tagged: alarm system, DSC alarm, program DSC alarm, security alarm system December 25, 2010
Addressing keypads is relatively straight forward. It entails adjusting each and every keypad to both exactly the identical address, as in some more mature panels preceding to the Vista P sequence that use non-addressable mode especially where all the keypads are founded to “31″, or to ascending addresses which in some belonging in the direction of more mature or bigger commercial panels start at “00″ and go up, or even the Vista P sequence that all start at “16″ and go up. Your set up handbook will inform you which addresses your method uses.
For this FAQ we’ll take advantage of the Vista 20P as an illustration as it’s one of the most common panel getting set up residentially today. however the method described could possibly be utilized on all addressable keypads.
1. The 20P utilizes the “16 – 23″ addresses for that traditional keypad’s (this does not consist of the graphic display keypads [AUI's] – see your handbook for those).
2. The method defaults to keypad tackle 16 “enabled”, (the relaxation belonging in the direction of keypads will should be enabled in programming starting with *190) Your key keypad must turn out to be addressed to “16″
3. swiftly upon energy up belonging in the direction of panel (or keypad) press and preserve the
1 & three keys reducing (this will show you the present keypad address)
4. Press “00″ (this will obvious the address)
5. Press the brand new tackle – inside the 20P this could possibly be “16″ (for the important thing keypad)
6. Press * to exit and help save the address. It will hold a 2nd as well as the show will start to show faults and so forth as normal.
7. If adding extra keypads they will start at “17″ and go as a terrific offer as “23″.
You should allow the relaxation belonging in the direction of keypads in programming (in the control panel) by entering programming and steering to *190 then press “1″ and “0″ (for common operations – see handbook for more) as this could “enable” keypad #17. hold on to *191 for keypad 18, *192 for 19 and so on.
Remember you need to continually possess a traditional alpha or fluid crystal display keypad attached in the direction of method – even if producing utilization of some belonging in the direction of graphic keypads (see their manuals for methods to tackle them) since the graphic keypads are not only a key keypad.
Posted in Uncategorized Tagged: Address alarm system, ADEMCO, alarm system, Contact ID alarm December 25, 2010
Name:
Wireless Auto Dialer Alarm System
Model: PH-T-4
Zones: 29 Wireless zones, 4 sensors for one zone
With Rechargeable Backup Battery

Wireless PSTN Alarm Systems
Main Features:
● LCD screen displays Date. Day of the week, Time, and current Armed Status
● Supported languages: Simple Chinese/Traditional Chinese/English/German/French/Russian and more.
● 29Wireless zones(Each zone supports up to 4 sensors) and 2 dedicated zones for remotes(Supports up to 4 remotes or wireless Keypads per zone)
● Can dial up to 5 phone numbers in sequence
● Arm/disarm the system by: Main Host(keypad),Wireless Keypad, Keychain Remotes, or even remotely by phone
● Record up to a 10 second greeting for the auto-dialer. Then play the greeting back.
● Wireless or wired siren are optional for louder alarming sound
● Alarm Sounds if Phone Line is Cut, auto priority to occupy the telephone and monitoring function to hear what is happening.
● Remembers programming settings when power is disconnected.
● Available in both AC/DC with Low-voltage Indicators
● Built-In Rechargeable Backup Battery (Keypad)
● More functions can be realized with more optional accessories(Note: consultation in advance is necessary)
Technical Parameter:
Working voltage:100~240VAC
Operating power: 9-15VDC
Wireless Frequency:433MHZ
Static current: ≤ 80mA
Alarm current: ≤ 500mA
Operating environment: Temperature: -10℃-50℃; Humidity:<90%
Maximum available quantity of keychain remotes: 4 PCS
Maximum available quantity of wireless sensors: 116 PCS
Dimension:180*120*5(mm)
Standard Package includes:
- Alarm system (control unit) – 1 pc.
- Wireless PIR detector – 1 pc.
- Wireless door (gap) sensor – 1 pc.
- Remote controller– 2 pcs.
- Antenna – 1pc.
- Wireless Sound&flash 110dB/0.3m – 1 pc.
- Power adpater – 1pc.
- User manual – 1pc.
Posted in Uncategorized Tagged: alarm systems, burglar alarm systems, home alarm systems, security alarm, telephone alarm system, wireless auto dialer June 8, 2010
Name:
Landline Alarm System
Model: PH-T-6
Zones: 15 Wireless zones, 4 sensors for one zone
With Rechargeable Backup Battery

Wireless Home Security Auto Dialer
Main Features:
● Easy-to-use and cost-effective D.I.Y. (do-it-yourself ) wireless intruder alarm
system kit.
● Supports up to 60 wireless sensors (15 wireless defense zones and 4 wireless
sensors per zone).
● Transmit at 430-433MHz frequency band, wireless transmitting distance up to 300 feet (Keychain remote, smoke sensor, & siren) and up to 450 feet (magnetic door/window sensor & PIR motion sensor)
● Can dial up to 5 phone numbers in sequence
● Arm/disarm the system by: Main Host (Keypad), Wireless Keypad, Keychain remotes, or even remotely by phone.
● Available in both ACDC with low-voltage Indicators.
● Programmable silent alarm or audible alarm.
● Recordable alarm voice message (up to 9 seconds record time).
● Telephone line disconnection alarm sound every 5 seconds.
● Smart 3 defense lines configuration: 1st defense line is the perimeter, 2nd defense line for in-room, & 24-hour defense line).
● Internal rechargeable backup battery in alarm host last up to 8 hours.
● Battery (alkaline) included for keychain remotes, wireless door sensor, and wireless motion sensor last up to 2 years.
● Remembers programming settings when power is disconnected.
● Ademco CID compatible protocol
Standard Package includes:
One alarm host
One wireless wide-rang PIR detector
One wireless door magnet
One wireless siren
Three remote controllers
One power supply.
Posted in Uncategorized Tagged: burglar alarm system, home alarm system, patrol alarm alarm, patrol hawk security, wireless alarm system, wireless auto dialer May 8, 2010

GSM Alarm Systems
GSM PSTN Alarm System-G60
Name: GSM Home Alarm System-G60
landline and GSM optional
Ademco contact ID through GSM
Main Features:
6 Group SMS, landline and GSM optional
Ademco contact ID through GSM
Programme the phone numbers directly on the panel
LCD and blue back-up light
85 event log, interphone function
6 groups timed auto arm/disarm, Away/Stay arm optional
Every zone can be programmed seperately
Every detector can be set to doorbell when disarmed
Every remote can be set to request assistance siren on/off
Siren could be set to sound when away arming
Unique watchdog function, monitor the old, patient or important place.
Built in rechargable battery;Built-in siren, and timer.
Technical Parameter:
Working voltage:100~240VAC
Operating power: 9-15VDC
GSM Frequency:900/1800MHZ, 850/900/1800/1900MHZ
Wireless Frequency:433MHZ
Static current: ≤ 80mA
Alarm current: ≤ 500mA
GSM transmission power: 2W
Operating environment: Temperature: -10-50; Humidity:90%
Wired Zone : 4
Wireless Zone: 8(Totally:51sensor)
Standard Package:
- Security Alarm system (control unit) 1 pc.
- Wireless PIR detector 1 pc.
- Wireless door (gap) sensor 1 pc.
- Remote controller 2 pcs.
- Antenna 1pc.
- Power adpater 1pc.
- User manual 1pc.
Posted in Uncategorized Tagged: dual network alarm, gsm alarm system, home alarm system, house security alarm, pstn alarm system, wireless security alarm May 2, 2010
Name:
GSM Home Alarm System-G40
Supprot CID Communication protocol
Preset 5 Telephone & SMS number

GSM Security Alarm System
Main Features:
Concise and elegant plastic house with simple operating interface
CID communication protocol
LCD screen with calender,GSM signal level
With 30 wireless alarm zones, GSM SMS alert and Telephone alarm
Can preset 5 groups telephone, with functions of recording, voice indicating and monitoring
Alarming Priority, log function, built-in back-up battery, AC/DC power both available
5 Arm/Disarm ways: Remote Controller, Host Keypad , Remote Controlling Keypad(options) , Telephone/Mobile phone and SMS
Outer power off inform via SMS
Technical Parameter:
Working voltage:100~240VAC
Operating power: 9-15VDC
GSM Frequency:900/1800MHZ, 900/1800/1900MHZ, 850/900/1800/1900MHZ
Wireless Frequency:433MHZ
Static current: ≤ 80mA
Alarm current: ≤ 500mA
GSM transmission power: 2W
Operating environment: Temperature: -10℃-50℃; Humidity:<90%
Maximum available quantity of keychain remotes: 4 PCS
Maximum available quantity of wireless sensors: 116 PCS
Dimension:180*120*5(mm)
Standard Package:
- Alarm system (control unit) – 1 pc.
- Wireless PIR detector – 1 pc.
- Wireless door (gap) sensor – 1 pc.
- Remote controller– 2 pcs.
- Antenna – 1pc.
- Wireless Sound&flash 110dB/0.3m – 1 pc.
- Power adpater – 1pc.
- User manual – 1pc.
Posted in Uncategorized Tagged: gsm alarm system, gsm security alarm, home alarm system, patrol hawk alarm, wireless alarm system, wireless security system May 2, 2010
Name: GSM Home Alarm System-G70

Touch Keypad Alarm Systems
Supprot CID Communication protocol
With Touch Screen
Main Features:
With Touch Screen of LCD Screen displays Date, Day of the week, Time, and current Armed Status
Supported Languages: Simple Chinese\ Traditional Chinese\ English\ German\ French\ Russian and more.
29 wireless zones (Each zone supports up to 4 sensors) and 2 dedicated zones for remotes (Supports up to 4 remotes or wireless keypads per zone)
8 more wired zones (Each zone supports 1 wired sensor), US$2.5 need to be added.
Can dial up to 5 phone numbers in sequence
Arm\ Disarm the system by: Main Host(Keypad), Wireless Keypad, Keychain Remotes, or even remotely by phones.
Check door\window status automatically (This is when the system is disarmed only, if a door is opened, it will sound fast “bi bi bi”)
Support wireless “ding-dong” doorbell function (Optional)
Non-volatile chip, information stored automatically when off power
Record up to a 10 second greeting for the auto-dialer, Then play the greeting back.
Alarm Sounds if Phone Line is Cut
Remembers programming settings when power is disconnected
Available in both AC\DC with Low-voltage Indicators.
Learn sensors to alarm host panel, very easy operation.
Supports Door. Window. Motion. Smoke. Heat. Glass Break. Gas Leak. Carbon Monoxide Detector. etc.
Support CID
Store 100 alarm records and 100 arm\disarm information.
Technical Parameter:
Working voltage:100~240VAC
Operating power: 9-15VDC
GSM Frequency:900/1800MHZ, 900/1800/1900MHZ, 850/900/1800/1900MHZ
Wireless Frequency:433MHZ
Static current: ≤ 80mA
Alarm current: ≤ 500mA
GSM transmission power: 2W
Operating environment: Temperature: -10℃-50℃; Humidity:<90%
Maximum available quantity of keychain remotes: 4 PCS
Maximum available quantity of wireless sensors: 116 PCS
Dimension:180*120*5(mm)
Standard Package:
- Touch screen Alarm system (control unit) – 1 pc.
- Wireless PIR detector – 1 pc.
- Wireless door (gap) sensor – 1 pc.
- Remote controller– 2 pcs.
- Antenna – 1pc.
- Wireless Sound&flash 110dB/0.3m – 1 pc.
- Power adpater – 1pc.
- User manual – 1pc.
Posted in Uncategorized Tagged: burglar alarm system, gsm alarm, home alarm system, house security alarm, wireless alarm system, wireless door alarm May 2, 2010
Previous Posts